Approvals & Certifications
Circuit Protection
- ESD Protection
- Over Current Protection
- Reverse Wiring Protection
Electrical Connectors
- Cable (J10 / J9T2A)
- R6 Typical
Element
- Sensing Element Design: PZT, Compression
Frequency
- Frequency Response (± 10 %): 1 to 7,000 Hz
- Frequency Response (± 3 dB): 0.5 to 15,000 Hz
- Frequency Response (± 5 %): 1.5 to 5,000 Hz
- Resonance Frequency: 25 kHz
Noise
- Electrical Noise, Equivalent G (Broadband: 2.5 Hz to 25 kHz): 600 µg
- Electrical Noise, Equivalent G (Spectral: 10 Hz): 8.0 µg/√Hz
- Electrical Noise, Equivalent G (Spectral: 100 to 1,000 Hz): 5 µg/√Hz
Non-Linearity
- Amplitude Non-Linearity: 1 %
Power Requirement
- 18-30 Vdc
- Current Regulating Diode: 2-10 mA
Range
- Acceleration Range, Vdc > 25 V: 80 G Peak
Sensitivity
- Base Strain Sensitivity: 0.0005 G/μstrain
- Sensitivity, ± 5 %, 25° C (77° F): 100 mV/g
- Transverse Sensitivity: Max. 5 % of axial
Temperature Range
- -50° to 120° C (-58° to 248° F)
Vibration
- Vibration Limit: 500 G Peak
Voltage
- Bias Output Voltage: 12 Vdc