Approvals & Certifications
Display
- 4-Digit, 7-Segment, 14(10) mm High, Red, Green, Blue or Orange LED
- Display Time: 0.1 to 10 seconds
- Horizontal bar (Up/Down) for Overflow/Underflow
Electrical Connectors
- Plug Terminals Cable Cross-Section up to 2.5 mm²
Enclosure, Body Material
- ASA 757 G Luran S - Field Housing
- Polycarbonate, Black
Gasket Material
- EPDM
- PU, -40° to 100° C (-40° to 212° F)
Measuring Error
- 0.1 % of Measuring Range, ± 1-Digit
- 0.2 % of Measuring Range, ± 1-Digit - Measuring Input (Pt1000/2-Wire)
- 2 K, ± 1-Digit - Measuring Input (Thermocouple)
Measuring Range
- 0(4)-20 mA / 0-10 Vdc - Measuring Input (Direct Current/Voltage)
- -270° to 1,820° C (-454° to 3,308° F)
Measuring Span
- -22 to 24 mA / -12 to 12 V - Measuring Input (Direct Current/Voltage)
Operating Temperature
- -40° to 80° C (-40° to 176° F)
Resistance
- 100 ohms (At 0(4) to 20 mA) - Input Resistance
- 100,000 ohms (At 0-10 Vdc) - Input Resistance
- 1E13 ohms - Surface Resistance
- Pluse Output 0 to 85 % Annual Mean, Non-Condensing - Weathering Resistance
Resolution
- 0.1° C
- Approximately 18-bit at 1 second Measuring Time
Sensor / Probe Type
- Thermocouples: Typical L, J, K, B, S, N, E, T, & R
Storage Temperature
- -20° to 80° C (-4° to 176° F)
Supply Voltage
- 115 Vac
- 230 Vac ± 10 %, 6 VA, Max.
- 24 Vac
- 24 Vdc, Galvanically Separated, Max.