Accuracy
- ± 0.5 % of Full Scale
- ± 1.0 % of Full Scale
Ambient Temperature Range
- -20° to 80° C (-4° to 176° F)
Applications
- Compressors
- Infusion Pumps
- Installations
- Machinery Industry
Circuit Protection
- Short Circuit Protection: 300 mA - Max.
Enclosure / Body Material
NPT Connection
- 1/2” NPT Male
- 1/4” NPT Male
Process Temperature
- -20° to 60° C (-4° to 140° F)
Proof Pressure
- 5800 psi: 1.5 x Range
- From 1450 psi: 2 x Range
- Up to 870 psi: 3x Range
Resolution
- psig: 0.14 (bar: 0.01, kPa: 1)
Response Time
- ± 0.5 % of Full Scale (± 1.0 % of Full Scale for Measuring Range of ≤ 1.6 bar)
Sensor / Probe Type
- Piezoresistive Ceramic Cell
Set Point - Decreasing
- bar: 0 to 399.9
- Inches Hg: -30 to 0
- kPa: 0 to 39,990
- psi: 0 to 5800
Set Point - Increasing
- bar: 0 to 399.9
- Inches Hg: -30 to 0
- kPa: 0 to 39,990
- psi: 0 to 5,800
System Pressure
- bar: 0 to 400
- Inches Hg: -30 to 0
- kPa: 0 to 39,990
- psi: 0 to 5,800