Materials
- Body: Thermoplastic, RTI 150° C
- Terminations: Tin-Plated Copper
Product Marking
- Brand logo, Voltage Rating, and Ampere Rating
Operating Temperature
- -55° to +100° C with proper derating
- Based on loading at 75 % of ampere rating when mounted using recommended pad layout
- Usage outside of stated operating temperature range requires testing in application. Maintain case temperature below 150° C in application
Thermal Shock
- MIL-STD-202, Method 107, Test Condition B (5 cycles -65° to 125° C)
Moisture Resistance
- MIL-STD-202 Method 106, High Humidity (90-98 % RH), Heat (65° C)
Vibration
- MIL-STD-202, Method 201 (10-55 Hz)
Mechanical Shock
- MIL-STD-202, Method 213, Test Condition I (100 G’s peak for 6 ms)
Resistance to Soldering Heat
- MIL-STD-202, Method 210, Test Condition B (10 sec at 260° C)
Salt Fog
- MIL-STD-202 Method 101 Test Condition B (5 % NaCl solution, 48 hours exposure)