LCI Inductive Conductivity/Concentration and Temperature Transmitter

Brand: KOBOLD Instruments, Inc

The device LCI is used for the measurement and control of the conductivity and respectively for concentrations of liquid media. The integrated temperature measurement makes exact and fast temperature compensation (linear and non-linear) possible, which is particularly important for the measurement of the conductivity. 

Additional functions such as the combined switching of the measurement range and temperature coefficient make possible the optimum use in case of CIP-processes. 

Two integrated switching outputs can be freely programmed for limit value monitoring or conductivity/concentration and/ or temperature. In addition, alarm and control tasks (desalination) can be assigned. 

Operation is either via a membrane keyboard and a plain text graphical display (user language can be changed) or via a comfortable PC-setup program. By simply turning the housing cover, reading the display is possible both in case of installation in vertical and horizontal pipes. 

By means of the setup program, the device configuration data can also be saved and printed for plant documentation purposes. The housing is specially produced out of stainless steel for use in the foodstuffs industry. 

The LCI can be supplied as a compact device (transmitter and measuring call in one device) or as a remote version (transmitter and measuring cell connected by cables). 

The remote version is particularly suitable for plants with intense vibrations and/or intense temperature radiation at the measurement location or for installation in inaccessible places.

Specifications

Accuracy

  • ≤ 0.5 % of Full Scale - Transmitter
  • ≤ 1 % of Full Scale - Transmitter
  • Thermal Error: ≤ 0.1 %/K (Ambient)

Alarm

  • High - Analog Output 22.0 mA / 0.7 V
  • Low - Analog Output 0 mA/0 V/3.4 mA/1.4 V

Ambient Temperature Range

  • 5° to 50° C (41° to 122° F) - Transmitter

Applications

  • Breweries & Dairies Systems
  • Chemical Processing Plants
  • CIP- Systems
  • Food & Beverage
  • Monitoring Bottle Cleaning Plants
  • Pharmaceutical
  • Water & Wastewater Engineering

BSP Connection

  • G 1-1/2” Male
  • G 2” Male

Compensated Temperature

  • -20° to 150° C (-4° to 302° F)

Consumption

  • ≤ 3 W - A/D Converter

Display

  • Graphic LCD with Background Lighting, Contrast Adjustable - A/D Converter

Electrical Connectors

  • M12 Plug/Sockets - A/D Converter
  • Threaded Plug Terminals 2.5 mm² - A/D Converter

Enclosure, Body Material

  • 303 Stainless Steel

Environmental Protection

  • IP67 - Transmitter

Function

  • Linear - Temperature Transmitter
  • Natural Water (EN 27 888)
  • Non-Linear

Humidity

  • Maximum

Load Impedance

  • ≤ 500 ohms - Current Output
  • ≥ 2 kiloohms Voltage Output - Temperature Transmitter
  • 2 kiloohms Voltage Output - Conductivity/Concentration Transmitter

Maximum System Pressure

  • psi: 145 (bar: 10, kPa: 1,000)

Measuring Range

  • 0 to 2000 ms/cm

Output

  • 0-10 V
  • 0-20 mA
  • 2 to 10 V
  • 4-20 mA

Power Requirement

  • 19 to 31 Vdc (Nominal 24 Vdc)

Process Temperature

  • -10° to 120° C (14° to 248° F)

Resolution

  • 15-bit - A/D Converter

Response Time

  • 500 milliseconds - A/D Converter

Sensor / Probe Material

  • PEEK (Polyetheretherketone)
  • PVDF (Polyvinylidenefluoride)

Storage Temperature

  • -10° to 75° C (14° to 167° F) - Transmitter

Temperature Effect

  • 0 to 5.5 %/K Adjustable - Temperature Coefficient

Temperature Range

  • -20° to 150° C (-4° to 302° F) - Transmitter
show more