Model 432.36+8xx, 432.56+8xx Diaphragm Pressure Gauge with Switch Contact

Brand: WIKA Alexander Wiegand SE & Co. KG

Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the model 432.56 or 432.36 switchGAUGE finds its use.

Switch contacts (electrical alarm contacts) make or break circuits dependent upon the pointer position of the indicating measuring instruments
Features
  • High overpressure safety, optionally up to 40, 100 or 400 bar, due to metallic diaphragm cushion, without liquidfilled measuring cell.
  • Wide choice of special materials.
  • Also available with liquid-filled case for high dynamic pressure loads or vibrations.
  • Gauges with inductive contacts for use in hazardous areas with ATEX approval.
  • Gauges with electronic contact for PLC applications.

Specifications

Nominal Size in mm

  • 100
  • 160

Accuracy Class

  • Option: 1.0
  • 1.6

Scale Ranges

  • other units (e.g. psi, kPa) available or all other Equivalent vacuum or combined Pressure and vacuum Ranges
  • 0 to 400 mbar to 0 to 40 bar (Flange Ø 100 mm)
  • 0 to 25 mbar to 0 to 250 mbar (Flange Ø 160 mm)

Scale

  • Option: Dual scale
  • Single scale

Pressure Limitation

  • Fluctuating: 0.9 x Full Scale Value
  • Steady: Full Scale Value

Overload Safety

  • 400 bar (Only for scale Ranges ≥ 0 ... 400 mbar)
  • 100 bar
  • 40 bar
  • Option: Vacuum safety to -1 bar

Process Connection with Lower Measuring Flange

  • Open Connecting Flange 2” Class 300, RF per ASME B16.5 and other threaded Connections and open Connecting Flanges per EN/ASME from DN 15 to DN 80 (See data sheet IN 00.10)
  • Open Connecting Flange 1” Class 300, RF per ASME B16.5
  • Open Connecting Flange DN 50 PN 40 per EN 1092-1, Form B
  • Open Connecting Flange DN 25 PN 40 per EN 1092-1, Form B
  • 1/2” NPT Female
  • 1/2” NPT
  • G 1/2 B

Permissible Temperature

  • Ambient: -20° to +60° C [-4° to +140° F]
  • Medium:  Option: +200° C [+392° F] Max.
  • Medium: +100° C [+212° F] Max.

Temperature Effect

  • When the temperature of the measuring system deviates from the reference temperature (+20° C): Max. ± 0.8 %/10 K of Full Scale Value

Case

  • Instruments with liquid filling with compensating valve to vent case
  • Model 432.36: Safety Version S3 per EN 837: with solid baffle wall (Solidfront) and blow-out back
  • Model 432.56: Version S1 per EN 837: with blow-out device in Case back

Case Filling

  • Without
  • Option: with Silicone oil M50 Case filling, ingress Protection IP65 (Models 433.56, 433.36)

  • Control and regulation of processes at measuring points with increased overpressure and scale ranges from 0 … 25 mbar
  • Monitoring of plants and switching of electric circuits
  • For gaseous and liquid, aggressive and highly viscous or contaminated media, also in aggressive environments
  • Process industry: Chemical, petrochemical, power plants, mining, on- and offshore, environmental technology, machine building and general plant construction

Documentation