TM Coriolis Mass Flowmeter

Brand: KOBOLD Instruments, Inc

The TM Series Mass Flow Meter utilizes the Coriolis principle of operation to measure mass flow. Density and temperature are simultaneously monitored and volumetric flow is additionally calculated with these parameters. The TM Series is available with a direct mounted transmitter or in a remote mounted configuration. 

The TM Series can be used to meter nearly all liquid or gaseous media. Available in a variety of end connections, the TM can be used in many applications. The TM Series is also used for precise dosing applications.

Specifications

Accuracy

  • ± 0.1 of Reading, ± Zero Point Stability - Liquids
  • ± 0.2 % of Reading, ± Zero Point Stability - Volume
  • ± 0.5 % of Reading, ± Zero Point Stability - Gas

Ambient Temperature Range

  • -20° to 60° C (-4° to 140° F) - Standard
  • -20° to 80° C (-4° to 176° F) - Remote Mounted
  • -40° to 100° C (-40° to 212° F) - Remote Version

Applications

  • Chemical & Petrochemical
  • Food Industry
  • Oil Ang Gas Industry

Approvals & Certifications

  • ASME B16.5
  • ASME Class 150, 300, 600
  • EN 1092
  • EN 61326
  • NEPSI

Communication

  • HART - Analog Output
  • Modbus RTU

Consumption

  • 1.8 W
  • 200 mA at 24 Vdc - Potential
  • 3 W

Cover Material

  • Safety Glass - Display Cover

Electrical Connectors

  • DIN 2512

Electromagnetic Rating

  • EMC-Directive 2004/108/EG

Enclosure / Body Material

  • 304 Stainless Steel
  • Aluminum

Environmental Protection

  • Intrinsically Safe
  • IP66
  • IP68 (EN 60529)

Flange Material

  • 316L Stainless Steel
  • 316Ti Stainless Steel
  • Hastelloy C-22
  • Monel
  • Nickel
  • Tantalum

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 150# ASME B16.5
  • 1” (DN 25) - PN 40

Flange Size - 1/2” (DN 15)

  • 1/2” (DN 15) - 150# ASME B16.5
  • 1/2” (DN 15) - 300# ASME B16.5
  • 1/2” (DN 15) - 600# ASME B16.5
  • 1/2” (DN 15) - PN 40

Flange Size - 2” (DN 50)

  • 2” (DN 50) - PN 40

Flange Size - 3” (DN 80)

  • 3” (DN 80) - PN 40

Flange Size - 3/8” (DN 10)

  • 3/8” (DN 10) - PN 40

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 300# ASME B16.5
  • 4” (DN 100) - 600# ASME B16.5
  • 4” (DN 100) - PN 16
  • 4” (DN 100) - PN 40

Flow Rate

  • 0-0.8 to 0-65,000 kg/h Water

Frequency

  • 1 kHz

Input

  • Active - Binary 1
  • Counter Reset - Input Binary

Materials of Construction

  • 316L Stainless Steel - Fow Tubes, Splitter
  • 316Ti Stainless Steel - Flow Tubes, Splitter
  • Hastelloy C-22 / B-2 - Flow Tubes, Splitter
  • Monel - Flow Tubes, Splitter
  • Nickel - Flow Tubes, Splitter
  • Tantalum - Flow Tubes, Splitter

Maximum System Pressure

  • psi: 580.2 (kPa: 4,000, bar: 40)

Media

  • Gas
  • Liquids

Mounting

  • Integrated
  • Remote Mounted

Nominal Pressure

  • psi: 580.2 (bar: 40, kPa: 4,000)

NPT Connection

  • 1/2” NPT Female
  • 1/4” NPT Female

Output

  • 200 mA
  • 24 V, 60 mA
  • 4-20 mA
  • Galvanically Isolated
  • Optocoupler
  • Passive
  • PROFIBUS-PA

Power Requirement

  • 19-36 Vdc
  • 24 Vac ± 5 % / -20 %
  • 30 Vdc
  • 50/60 Hz
  • 90-265 Vac

Process Temperature

  • -40° to 260° C (-40° to 500° F)

RFI/EMI Effect

  • EN 61000-6-3: 2001 - Electromagnetic Compatibility

Temperature Range

  • -40° to 260° C (-40° to 500° F)
show more