UMC Transmitter for TM, TME & TMU Flowmeters

Brand: KOBOLD Instruments, Inc

The TM Series Mass Flow Meter utilizes the Coriolis principle of operation to measure mass flow. Density and temperature are simultaneously monitored and volumetric flow is additionally calculated with these parameters.

The TM Series is available with a direct mounted transmitter or in a remote mounted configuration. The TM Series can be used to meter nearly all liquid or gaseous media. Available in a variety of end connections, the TM can be used in many applications. The TM Series is also used for precise dosing applications.
Features
  • Superior Accuracy
  • Industry's widest selection of wetted materials
  • Thick pipe wall construction

Specifications

Accuracy

  • ± 0.1 % of Reading, ± Zero Point Stability - Liquid
  • ± 0.15 % of Reading, ± Zero Point Stability - Liquid
  • ± 0.2 % of Reading, ± Zero Point Stability - Volume
  • ± 0.5 % of Reading, ± Zero Point Stability - Gas

Ambient Temperature Range

  • -20° to 80° C (-4° to 176° F)

Approvals & Certifications

  • BVS 05-ATEX-E 021 X
  • CE
  • Ex
  • FM
  • IEC
  • NEPSI

Communication

  • HART
  • Modbus RTU (RS-485)
  • PROFIBUS PA

Cover Material

  • Safety Glass

Electrical Connectors

  • Junction Box
  • M20 x 1.5
  • Plug Connection

Electromagnetic Interference Effect

  • EMC-Directive 2004/108/EG

Electromagnetic Rating

  • EMC-Directive 2004/108/EC
  • EMV-Guide Line 2004/108/EC

Enclosure / Body Material

  • Aluminum (Painted)

Environmental Protection

  • Intrinsically Safe
  • IP68

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 150 ASME B16.5
  • 1” (DN 25) - PN 40

Flange Size - 1/2” (DN 15)

  • 1/2” (DN 15) - 150 ASME B16.5
  • 1/2” (DN 15) - PN 40

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150 ASME B16.5
  • 2” (DN 50) - PN 40

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150 ASME B16.5
  • 3” (DN 80) - PN 40

Flange Size - 3/4” (DN 20)

  • 3/4” (DN 20) - 150 ASME B16.5

Flange Size - 3/8” (DN 10)

  • 3/8” (DN 10) - PN 40

Frequency

  • 1 kHz
  • 50/60 Hz

Input

  • 1.8 W
  • 200 mA
  • 24 V
  • 3 W
  • 30 V
  • 60 mA
  • Counter Reset

Mounting

  • Integral Mounting
  • Remote Mounting

NPT Connection

  • 1/2” NPT Male

Output

  • 30 V
  • 4-20 mA
  • Galvanically Isolated
  • Optocoupler
  • Passive

Power Requirement

  • 19-36 Vdc
  • 24 Vac ± 20 %
  • 90-265 Vac

Process Temperature

  • -40° to 180° C (-40° to 356° F)

Response Time

  • 50 milliseconds

RFI/EMI Effect

  • EN 61000-6-2: 1999 Immunity
  • EN 61000-6-3: 2001 Emissions
show more