Excitation Frequency (Mains Supply: 50 Hz/60 Hz)
- DN 2 … 65 (1/12” … 2-1/2”): 12.5 Hz/15 Hz
- DN 80, 100 (3”, 4”): 6.25 Hz/7.5 Hz
Process Connection Nominal Size
- MAG 1100 (Ceramic) DN 2 … DN 100 (1/12” … 4”)
- MAG 1100 (PFA) DN 10 … DN 100 (3/8” … 4”)
Mating Flanges
- EN 1092-1 (DIN 2501), ANSI B 16.5 Class 150 and 300 or equivalent
- Option: DN 2 … 10 (1/12” … 3/8”): G1/2”/NPT 1/2” pipe connection adapters
Ambient Temperature
- Standard sensor -40 … +100° C (-40 … +212° F)
- Ex sensor -20° to +60° C (-4 … +140° F)
- Compact with transmitter MAG 5000/6000 -20 … +60° C (-4 … +140° F)
- Compact with transmitter MAG 6000 I -20 … +60° C (-4 … +140° F)
- Compact with transmitter MAG 6000 I Ex -20 … +60° C (-4 … 140° F)
Temperature of Medium
- MAG 1100 (Ceramic) -20 … +150° C (-4 … +302° F)
- MAG 1100 Ex (Ceramic) -20 … +150° C (-4 … +302° F)
- MAG 1100 (PFA) -30 … +130° C (-22 … +266° F)
- Suitable for steam sterilization at 150° C (302° F)
Temperature Shock MAG 1100 (Ceramic) - Duration ≤ 1 min, Followed By 10 Min Rest
- DN 2, 3 (1/12”, 1/8”) No limitations
- DN 6, 10, 15, 25: Max. ΔT ≤ 80° C/min (1/4”, 3/8”, 1/2”, 1”: Max. ΔT ≤ 144° F/min)
- DN 40, 50, 65: Max. ΔT ≤ 70° C/min (1-1/2”, 2”, 2-1/2”: Max. ΔT ≤ 126° F/min)
- DN 80, 100: Max. ΔT ≤ 60° C/min (3”, 4”: Max. ΔT ≤ 108° F/min)
Temperature Shock MAG 1100 (PFA)
- Maximum ± 100° C (212° F) momentarily
Operating Pressure MAG 1100 (Ceramic)
- DN 2 … 65: 40 bar (1/12” … 2-1/2”: 580 psi) •
- DN 80: 37.5 bar (3”: 540 psi)
- DN 100: 30 bar (4”: 435 psi)
- Vacuum: 1 x 10-6 barabs (1.5 x 10-5 psiabs)
Operating Pressure MAG 1100 (PFA)
- 20 bar (290 psi)
- Vacuum: 0.02 barabs (0.3 psiabs)
- DN 80 … DN 100: CO₂ pressure Max. 7 bar (101.5 psi)
Mechanical Load (Vibration)
- 18 … 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36
- Sensor: 3.17 g rms
- Sensor with compact MAG 5000/6000 mounted transmitter: 3.17 g rms
- Sensor with compact MAG 6000 I/6000 I Ex mounted transmitter: 1.14 g rms
- For compact installation with the MAG 6000 I, transmitter to be supported to avoid tension on sensor part.
Enclosure Rating (Standard)
- IP67 to EN 60529 (NEMA 4X), 1 mH₂O for 30 min
- EMC - 2014/30/EU
Enclosure Material
- MAG 1100 - Stainless Steel AISI 316L/1.4404
Terminal Box Material
- Standard - Fibre glass reinforced polyamide (Not for Ex)
- Option - Stainless Steel AISI 316/1.4436
Fixing Studs Material
- Stainless Steel AISI 304/1.4301
- Number and size to EN 1092-1: 2001
Gaskets Material Standard
- EPDM (Max. 150° C, PN 40 (Max. 302° F, 600 psi))
Gaskets Material Option
- Graphite (Max. 200° C, PN 40 (Max. 392° F, 600 psi))
- PTFE (Max. 130° C, PN 25 (Max. 266° F, 300 psi))
- Stainless Steel, AISI 316 /1.4436
Pipe Connection Adapters Material DN 2, 3, 6 and 10 (1/12”, 1/8”, ¼" and 3/8”)
- Hastelloy C-22/2.4602
- PVDF
Liner MAG 1100 (Ceramic)
- DN 2, 3 (1/12”, 1/8”): Zirconium oxide (ZrO₂) (ceramic)
Liner MAG 1100 (PFA)
- DN 6 … 100 (1/4” … 4”): Aluminum oxide Al2O3
- Reinforced PFA (Not for Ex)
Electrodes MAG 1100 (Ceramic)
- DN 10 … 100 (3/8” … 4”): Platinum with gold/Titanium brazing alloy
Electrodes MAG 1100 (PFA)
- DN 2 … 6 (1/12” … 1/4”): Platinum
- DN 10 … 15 (3/8” … 1/2”): Hastelloy C-276/2.4819
- DN 25 … 100 (1” … 4”): Hastelloy C-22/2.4602
Cable Entries
- Remote installation 2 x M20 or 2 x 1/2” NPT
- Compact installation - MAG 5000/MAG 6000: 4 x M20 or 4 x 1/2” NPT, MAG 6000 I: 2 x M25 (for supply/output), MAG 6000 I Ex: 2 x M25 (for supply/output)