Measuring Range
- 0.25... 5 m (0.8... 16.4 ft)
Output - mA
- 4... 20 mA
- Span - Proportional/ inversely proportional
- Maximum load - 750 Ω at 24 Vdc
Supply Voltage
- 18 ... 30 Vdc, Max. 0.2 A
Maximum Power Consumption
Error in Measurement
- 0.25 % of Measuring Range (in air)
Ambient Temperature
- Standard: -40° to +60° C (-40° to +140° F)
- Metallic mounting: -20° to +60° C (-4° to +140° F)
Storage Temperature
- Standard: -40° to +60° C (-40° to +140° F)
- Metallic mounting: -20° to +60° C (-4° to +140° F)
Maximum Static Operating Pressure
- Normal Atmospheric Pressure
Weight
- Without flange adapter: 1.5 kg (3.3 lb)
- With flange adapter: 1.7 kg (3.7 lb)
Material
- Electronics enclosure: PVC
- Transducer: PVDF copolymer
Process Connection
- 2” NPT [(Taper), ANSI/ASME B1.20.1]
- R 2” [(BSPT), EN 10226]
- G 2” [(BSPP), EN ISO 228-1]
- 4” sanitary
Flange Adapter
- 3” Universal (fits DN 65, PN 10 and 3” ASME )
Cable Inlet
- 2 inlets for PG 16
- 1/2” NPT cable glands