Approvals & Certifications
- ATEX II 1 G Ex ia IIC T4 Ga -50° C ≤ Ta ≤ 120° C
- CE
- CSA (C,US) Class I, Div. 1, Grade A, B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, Class I, Zone 0, Ex ia IIC T4 Class I, Zone 0, AEx ia IIC T4 Tamb: -50° to 120° C
- IEC, IECEx
Circuit Protection
- ESD Protection
- Reverse Wiring Protection
Electrical Connectors
- Integral Cable (J9T2A, 16 feet, Blunt Cut)
Element
- Sensing Element Design: PZT, Shear
Frequency
- Frequency Response (± 10 %): 1 to 8,000 Hz
- Frequency Response (± 3 dB): 0.5 to 13,000 Hz
- Resonance Frequency: 30 kHz
Noise
- Electrical Noise, Equivalent G (Broadband: 2.5 Hz to 25 kHz): 700 µg
- Electrical Noise, Equivalent G (Spectral: 10 Hz): 10 µg/√Hz
- Electrical Noise, Equivalent G (Spectral: 100, 1,000 Hz): 5 µg/√Hz
Non-Linearity
- Amplitude Non-Linearity: 1 %
Power Requirement
- 18-30 Vdc
- Current Regulating Diode: 2-10 mA
Range
- Acceleration Range, Vdc > 22 V: 80 G Peak
Sensitivity
- Base Strain Sensitivity, Max.
- Electromagnetic Sensitivity, Equivalent G, Max.
- Sensitivity, ± 5 %, 25° C (77° F): 100 mV/g
- Transverse Sensitivit: Max. 5 % of axial
Shock
- Shock Limit: 5,000 G Peak
Static Pressure
- Hydrostatic Pressure - psi: 100 (kPa: 689.5, bar: 6.89)
Temperature Range
- -50° to 120° C (-58° to 248° F)
Vibration
- Vibration Limit: 500 G Peak
Voltage
- Bias Output Voltage: 12 Vdc