NSC Capacitive Level Limit Switch

Brand: KOBOLD Instruments, Inc

The KOBOLD level monitor devices model NSC are used for the monitoring of minimum and maximum levels in silos and depots. They are working on the capacitive principle and can be supplied in two different designs. They are suitable for various installation conditions. 

The level monitoring device NSC-R is supplied with a rigid stainless steel probe with a PTFE coating. 

This model is mostly used for monitoring the maximum level. For small silos and low bulk densities the short version can also be installed on the side for controlling of the minimum level. 

The level monitor device NSC-C consists of a stainless steel probe body, which is connected to the connection box by means of a steel cable coated with polypropylene. 

The cable can be shortened by the customer, making an adaptation to changing application conditions very easy. This type is usually used to control the maximum level, but also for the minimum in case of low bulk densities. 

There is a non-sensitive section close to the mounting thread to avoid false alarms in case of deposits. For adaptation to the kind of media and its density or the shape of the silo, the sensitivity can be adjusted via a DIP-switch or a potentiometer.

Specifications

Ambient Temperature Range

  • -20° to 60° C (-4° to 140° F)

Applications

  • Animal Feed, Flour
  • Cement
  • Food
  • Mineral Products
  • Sands & Gravel

Approvals & Certifications

  • ATEX
  • Ex II 2/1 ExtD (IaD)iaD T85° C

BSP Connection

  • G 1” Male
  • G 1-1/2” Male
  • G 1-1/4” Male

Cable Length

  • 49.2' (15 m)

Cable Material

  • Steel Cable with PP Coating

Connection Material

  • 303 Stainless Steel

Electrical Connectors

  • M20 x 1.5 Cable Gland

Electrical Rating

  • Maximum

Enclosure / Body Material

  • Aluminum with ATEX
  • Polycarbonate

Enclosure Finish

  • Polypropylene

Environmental Protection

  • IP65

Input Power

  • 1 VA

Length

  • 10.43” to 118.1” (265 to 3000 mm) - Immersion Length (NSC-R)
  • Maximum

Maximum System Pressure

  • psi: -1.45 to 7.252 (kPa: -10 to 50, bar: -0.1 to 0.5)

Mounting Position

  • Vertical - NSC-C
  • Vertical/Inclined - NSC-R

Orifice Size

  • 1.57” (40 mm)

Output Format

  • Relay Output

Process Temperature

  • -20° to 80° C (-4° to 176° F) - Max.

Sensor / Probe Material

  • 303 Stainless Steel with PTFE Coating
  • Polypropylene - Isolation Piece

Supply Voltage

  • 110 Vac
  • 18-36 Vdc
  • 230 Vac
  • 24 Vac
  • 50/60 Hz

show more