Scale Ranges
- 0 to 2.5 mbar to 0 to 100 mbar other units (e.g. psi, kPa) available
- Or all other equivalent vacuum or combined pressure and vacuum ranges
Scale
- Single scale
- Option: Dual scale
Pressure Limitation
- Steady: Full Scale Value
- Fluctuating: 0.9 x Full Scale Value
Overload Safety
- 50 x Full Scale Value
- Higher overload safety on Request
Process Connection with Lower Measuring Flange
- M20 x 1.5
- Others on Request
- G 1/2 B
- 1/2” NPT
Permissible Temperature
- Ambient: -20° to +60° C [-4° to 140° F]
- Medium: +100° C [+212° F] Max.
Temperature Effect
- When the temperature of the measuring system deviates from the reference temperature (+20° C): Max. ± 0.6 %/10 K of Full Scale Value
Case
- Version S1 per EN 837: with blow-out device in Case back
Zero Point Setting
- By means of Adjustment appliance
Wetted Materials
- Process Connection, media chamber, capsule Element (Pressure Element): Stainless Steel 316Ti
- Sealing: PTFE
Non-Wetted Materials
- Case, movement, bayonet Ring: Stainless Steel
- Instrument Pointer: Aluminium, Black
- Set Pointer: Aluminium, Red
- Window: Laminated Safety Glass
- Dial: Aluminium, White, Black Lettering
Ingress Protection Per IEC / EN 60529
Mounting
- Rigid Measuring line
- Option:
- Instrument Mounting bracket for wall or pipe Mounting
- Mounting flang