Price
$306.00 CAD
Stock
50+ In Stock

  • Unit - Meter H2O
  • Measuring Range - Meter H2O: 0 to 60
  • Material - Stainless Steel, FEP Cable
  • Accuracy - 0.5 % of Span (0.25 % BFSL)
  • Cable Length - 5 Feet

Specifications

Accuracy

  • ≤ ± 0.25 % of Span - Including Non-Linearity, Hysteresis, Zero Offset & End Value Deviation (Corresponds to Measured Error Per IEC 61298-2)
  • ≤ ± 0.5 % of Span

Ambient Temperature Range

  • -30° to 105° C (-22° to 221° F)

Applications

  • Brackish Water & Fuel Tanks in Shipbuilding
  • Mining & Gas Extraction
  • Oil & Fuel Storage Tanks
  • Wastewater Treatment & Biogas Production

Approvals & Certifications

  • ATEX - Ex I, Zone 1 Gas, [II 2 G Ex ia IIC T4/T5/T6 Gb]
  • ATEX - Mining, [I M1 Ex ia I Ma]
  • ATEX - Zone 0 Gas, [II 1 G Ex ia IIA T4/T5/T6 Ga]
  • ATEX - Zone 1 Mounting to Zone 0 Gas, [II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb]
  • ATEX - Zone 20 Dust, [II 1D Ex ia IIIC T120° C Da]
  • BelCT
  • CE
  • CRN - Safety (e.g. Electr. Safety, Overpressure, to), Canada
  • CSA - Canadian Zone Designation: Class I, Zone 0, Ex ia, IIC, IP65, DIP A20
  • CSA - Hazardous Areas, Class I, Div. 1, Groups A, B, C, D. Class II, Groups E, F, G, Class III.
  • CSA - Safety (e.g. Electr. Safety, Overpressure, to)
  • CSA - US Zone Designation: Class I, Zone 0, AEx ia, IIC, IP65
  • EAC - Hazardous Areas, Ex I, Zone 1 Gas, [1ExiaIICT4/T5/T6 X]
  • EAC - Mining, [POExiaI X]
  • EAC - Zone 0 Gas, [0ExiaIIAT4/T5/T6 X]
  • EAC - Zone 1 Mounting to Zone 0 Gas, [1ExiaIICT4/T5/T6 X]
  • EAC - Zone 20 Dust, [Ex iaD 20 T80° C X]
  • EMC
  • EN 61326 Emission (Group 1, Class B) & Interference Immunity (Industrial Application)
  • Ex
  • FM - Class I, Zone 0, AEx ia IIC
  • FM - Dust Ignition-proof for Class II, III, Div. 2, Groups F, G
  • FM - Hazardous Areas, Intrinsically Safe Class I, II & III, Div. 1, Grade A, B, C, D, E, F, G
  • GL - Ships, Shipbuilding (e.g. Offshore)
  • GOST
  • IECEx - Hazardous Areas, Ex I, Zone 1 Gas, [Ex ia IIC T4/T5/T6 Gb]
  • IECEx - Mining, [Ex ia I Ma]
  • IECEx - Zone 0 Gas, [Ex ia IIA T4/T5/T6 Ga]
  • IECEx - Zone 1 Mounting to Zone 0 Gas, [Ex ia IIC T4/T5/T6 Ga/Gb]
  • IECEx - Zone 20 Dust, [Ex ia IIIC T120° C Da]
  • INMETRO - Hazardous Areas, Ex I, Zone 1 Gas, [Ex ia IIC T4/T5/T6 Gb]
  • INMETRO - Metrology, Measurement Technology
  • INMETRO - Mining, [Ex ia I Ma]
  • INMETRO - Zone 0 Gas, [Ex ia IIA T4/T5/T6 Ga]
  • INMETRO - Zone 1 Mounting to Zone 0 Gas, [Ex ia IIC T4/T5/T6 Ga/Gb]
  • INMETRO - Zone 20 Dust, [EX Ia IIIC T120° C Da]
  • KazlnMetr
  • UkrSEPRO
  • UZSTANDARD

BSP Connection

  • G 1/2” B Male
  • G 1/4” Female Thread (Only in Hastelloy)

Cable Material

  • FEP
  • Polyurethane

Enclosure, Body Material

  • 316L Stainless Steel
  • Hastelloy

Environmental Protection

  • IP68

Non-Linearity

  • ≤ ± 0.2 % of Span

Output

  • 4-20 mA, 2-Wire

Overpressure & Static Pressure Limits

  • psi: 55 to 360 (kPa: 380 to 2.480, bar: 3.8 to 24.8)

Power Supply

  • 10-30 Vdc

Pressure Range

  • bar: 0 to 25
  • Inches WC: 0 to 250
  • kPa: 0 to 2,500
  • psi: 0 to 300

Pressure Type

  • Gauge

Repeatability

  • Non-Repeatability: ≤ ± 0.1 % of Span

Storage Temperature

  • -10° to 60° C (14° to 140° F)

Temperature Range

  • -30° to 105° C (-22° to 221° F)

Wetted Materials

  • 316L Stainless Steel
  • FEP
  • Hastelloy
  • Polyurethane
show more