Price
$2,500.00 CAD
Stock
100+ In Stock

  • Measuring Range - 2,000 to 20,000 kg/hour (lbs/min)

Specifications

Accuracy

  • ± 0.1 % of Reading, ± Zero Point Stability up to TMR040
  • ± 0.15 % of Reading, ± Zero Point Stability from TMR080

Ambient Temperature Range

  • -20° to 80° C (-4° to 176° F) - Special Version
  • -40° to 100° C (-40° to 212° F) - Remote Mounted Transmitter

Applications

  • Chemical & Petrochemical
  • Oil Industries

Approvals & Certifications

  • ASME B16.5
  • ASME Class 150, 300, 600 - Standard
  • DMT 01-ATEX-E 149 X
  • EN 1092
  • PED 97/23/EC

Communication

  • HART
  • Modbus RTU (RS-485)
  • PROFIBUS PA

Consumption

  • 200 mA at 24 Vdc
  • 3 W

Electrical Connectors

  • Junction Box
  • Plug Connection

Enclosure / Body Material

  • 304 Stainless Steel
  • 304L Stainless Steel up to TMR040

Environmental Protection

  • Intrinsically Safe - Sensor Circuits
  • IP65
  • IP68 (EN 60529)
  • NEMA 4X
  • NEMA 6

Flange Material

  • 316L Stainless Steel
  • 316Ti Stainless Steel

Flange Size - 1-1/2” (DN 40)

  • 1-1/2” (DN 40) - 150# ASME
  • 1-1/2” (DN 40) - 300# ASME
  • 1-1/2” (DN 40) - 600# ASME

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 150# ASME
  • 1” (DN 25) - 300# ASME
  • 1” (DN 25) - 600# ASME
  • 1” (DN 25) - PN 40

Flange Size - 2-1/2” (DN 65)

  • 2-1/2” (DN 65) - PN 40

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150# ASME
  • 2” (DN 50) - 300# ASME
  • 2” (DN 50) - 600# ASME
  • 2” (DN 50) - PN 40

Flange Size - 3/4” (DN 20)

  • 3/4” (DN 20) - 150# ASME
  • 3/4” (DN 20) - 300# ASME
  • 3/4” (DN 20) - 600# ASME
  • 3/4” (DN 20) - PN 40

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150# ASME
  • 4” (DN 100) - 300# ASME
  • 4” (DN 100) - 600# ASME
  • 4” (DN 100) - PN 40

Frequency

  • 1 kHz

Input

  • 200 mA
  • 30 V
  • Active
  • Counter Reset - Input Binary

Materials of Construction

  • 316L Stainless Steel - Flow Tubes, Splitter
  • 316Ti Stainless Steel - Flow Tubes, Splitter

Mounting

  • Integrated
  • Remote Mounting

Nominal Pressure

  • psi: 580.2 (bar: 40, kPa: 4,000)

Output

  • 30 V
  • 4-20 mA
  • Galvanically Isolated
  • Optocoupler
  • Passive

Power Requirement

  • 19-36 Vdc
  • 24 Vac ± 20 %
  • 90-265 Vac

Process Temperature

  • -40° to 260° C (-40° to 500° F)

RFI/EMI Effect

  • EMC-Directive 89/336/EEC
  • EN 61000-6-3: 2001 (Emissions Residential Environments), EN 61000-6-2: 1999 (Immunity for Industrial Environments)
show more